Weg CFW11 VSD Repairs

Model:  AFW110105T4ODBFAYWZ

Part Number: EUAFW110105T4ODBFAYWZ

Range: AFW11

ND Current Rating: 105 amps

Frame: E

User Guide: Link to PSD

Preventive Maintenance Service Work

  • Periodic Inspection
    • Terminal Blocks, Connectors
    • Fans/Ventilation System replacement
    • Printed Circuit Board
    • Power Module/Power Connectors
    • DC Link capacitor reforming
    • DC Link capacitor replacement
    • Power Resistors
  • Power capacitor regeneration (reforming)
    • Can be performed at your site/warehouse or at our workshop
    • Send us your VSD, or we’ll come to you
  • Fan Replacement

Corrective Maintenance Work

  • We’ll fix your VSD and have you back in production in no time.
  • Ask us about a replacement drive also.
  • IGBT & power arm replacement
  • Firing board replacement
  • Gate Driver board, Gate Resistor board replacement
  • DFO board replacement
  • CC11 Control Board replacement
  • Capacitor bank replacement
  • Input Rectifier replacement
  • Load Testing

ASAP Power - Preferred Authorized Weg Service Centre

ASAP Power is the preferred authorized Weg Service Centre of many mining and manufacturing customers.

Our fully equipped workshop carries comprehensive spare parts for Weg Automation products.  This allows us to quickly and effectively diagnose problems with your VSDs and Soft starters.  Repairs are a much more economic solution to replacement of the drive as it is done at a fraction of the cost and most drives are repaired within a week.

How Does It Work?

  1. Send us your VSD along with a description of the problem you are having
  2. We inspect the VSD and provide you with an inspection report and a fixed price quote for repair or replacement
  3. An inspection fee of $350.00 applies regardless if you choose to go ahead with the repair or replacement
  4. Call or email today to get started!

The ASAP Power Advantage

  • Factory trained service personnel·
  • Fully stocked spares part warehouse (Largest spare parts stock in WA)
  • Engineers with 25+ years experience with drive repairs
  • All work is tested & comes with warranty
  • If we can’t fix the problem, the work is free!

We can rectify the below faults with your AFW110105T4ODBFAYWZ

F006 – IMBALANCE OR INPUT PHASE LOSS
A010 – RECTIFIER HIGH TEMPERATURE
F011 – RECTIFIER OVERTEMPERATURE
F021 – DC BUS UNDERVOLTAGE
F022 – DC BUS OVERVOLTAGE
F030 – POWER MODULE U FAULT
F034 – POWER MODULE V FAULT
F038 – POWER MODULE W FAULT
F042 – DB IGBT FAULT
A046 – HIGH LOAD ON MOTOR
F072 – MOTOR OVERLOAD
A047/F048 – IGBT OVERLOAD
A050 – IGBT HIGH TEMPERATURE U
F051 – IGBT OVERTEMPERATURE U
A053 – IGBT HIGH TEMPERATURE V
F054 – IGBT OVERTEMPERATURE V
A056 – IGBT HIGH TEMPERATURE W
F057 – IGBT OVERTEMPERATURE W
F062/A417 – THERMAL IMBALANCE
F065/F066 – ENCODER SIGNALS FAULT (SW)
F067 – INCORRECT ENCODER/MOTOR WIRING
F070 – OVERCURRENT/SHORT-CIRCUIT
F071 – OUTPUT OVERCURRENT
F074 – GROUND FAULT
F076 – MOTOR CURRENT IMBALANCE
F077 – DB RESISTOR OVERLOAD
F078 – MOTOR OVERTEMPERATURE
A110 – HIGH MOTOR TEMPERATURE
F079 – ENCODER SIGNAL FAULT
F080 – CPU WATCHDOG
F082 – COPY FUNCTION FAULT
F084 – SELF-DIAGNOSIS FAULT
A088 – KEYPAD COMMUNICATION FAULT
A090 – EXTERNAL ALARM
F091 – EXTERNAL FAULT
F099 – INVALID CURRENT OFFSET
A128/F228 – TIMEOUT FOR SERIAL COMMUNICATION
A129/F229 – ANYBUS IS OFFLINE
A130/F230 – ANYBUS ACCESS ERROR
A133/F233 – CAN NOT POWERED
A134/F234 – BUS OFF
A135/F235 – CANOPEN COMMUNICATION ERROR (NODE GUARDING)
A136/F236 – IDLE MASTER
A137/F237 – DEVICENET CONNECTION TIMEOUT
A138/F238 – PROFIBUS DP INTERFACE IN CLEAR MODE
A139/F239 – PROFIBUS DP INTERFACE OFFLINE
A140/F240 – PROFIBUS DP MODULE ACCESS ERROR
F150 – MOTOR OVERSPEED
F151 – FLASH MEMORY MODULE FAULT
A152 – INTERNAL AIR HIGH TEMPERATURE
F153 – INTERNAL AIR OVERTEMPERATURE
A155/F156 – UNDERTEMPERATURE
F160 – SAFETY STOP RELAYS; STO; SAFE TORQUE OFF
F161 – TIMEOUT PLC11 CFW11
A162 – INCOMPATIBLE PLC FIRMWARE
A163 – BREAK DETECT AI1
A164 – BREAK DETECT AI2
A165 – BREAK DETECT AI3
A166 – BREAK DETECT AI4
F174 – LEFT FAN SPEED FAULT
F175 – CENTER FAN SPEED FAULT
F176 – RIGHT FAN SPEED FAULT
A178 – FAN SPEED FAULT
F179 – HEAT SINK FAN SPEED FAULT
A177 – FAN REPLACEMENT
A181 – INVALID CLOCK VALUE
F182 – PULSE FEEDBACK FAULT
F183 – IGBT OVERLOAD + TEMPERATURE
F185 – PRE-CHARGE CONTACTOR FAULT (FRAME SIZE E)
F185 – PRE-CHARGE FAULT (FRAME SIZE H)
F186 F187 F188 F189 F190 – SENSOR 1 TO 5 TEMPERATURE FAULT
A191 A192 A193 A194 A195 – SENSOR 1 TO 5 TEMPERATURE ALARM
A196 A197 A198 A199 A200 – SENSOR 1 TO 5 CABLE ALARM
F416 – IGBT CURRENT IMBALANCE FAULT
F418 – CONTROL AIR OVERTEMPERATURE
A419 – CONTROL AIR HIGH TEMPERATURE
A700/F701 – DETACHED HMI
A702 – INVERTER DISABLED
F704 – TWO MOVEMENTS ENABLED
A706 – NOT PROGRAMMED REFERENCE SOFTPLC