Weg SSW06 Softstarter Repairs

Model: SSW060312T5769EOIPZ

Part Number: EUSSW060312T5769EOIPZ

Range: SSW06

ND Current Rating: 312 amps

Frame: 4

User Guide: Link to PDF

Preventive Maintenance Service Work

  • Periodic Inspection
    • Terminal Blocks, Connectors
    • Fans/Ventilation System replacement
    • Printed Circuit Board
    • Power Module/Power Connectors
    • SCR/Thyristor (module or Disc) inspection
    • Power Resistors
  • Firmware updates & upgrades
  • Fan Replacement

Corrective Maintenance Work

  • We’ll fix your Softstarter and have you back in production in no time.
  • Ask us about a replacement soft starter also.
  • Thyristor / SCR & power arm replacement
  • Firing board replacement
  • Fan Replacement

ASAP Power - Preferred Authorized Weg Service Centre

ASAP Power is the preferred authorized Weg Service Centre of many mining and manufacturing customers.

Our fully equipped workshop carries comprehensive spare parts for Weg Automation products. This allows us to quickly and effectively diagnose problems with your VSDs and Soft starters. Repairs are a much more economic solution to replacement of the drive as it is done at a fraction of the cost and most drives are repaired within a week.

How Does It Work?

  1. Send us your Soft Starter along with a description of theproblem you are having
  2. We inspect the Soft Starter and provide you with an inspection report and a fixed price quote for repair or replacement
  3. An inspection fee of $200.00 applies regardless if you choose to go ahead with the repair or replacement
  4. Call or email today to get started! We are also authorized to undertake warranty inspections of your Weg Automation products.

Wecan rectify the below faults with your SSW060312T5769EOIPZ

E03 – UNDERVOLTAGE, PHASE FAULT OR VOLTAGE UNBALANCING
E04 – OVERTEMPERATURE AT THE POWER ASSEMBLY
E05 OR A05 – MOTOR OVERLOAD
E06 OR A06 – EXTERNAL FAULT OR ALARM (DI)
E10 – COPY FUNCTION FAULTE11 – GROUND FAULT
E15 – MOTOR IS NOT CONNECTED OR SCRS IN SHORT-CIRCUIT
E16 OR A16 – OVERVOLTAGEE18 – WRONG MOTOR CONNECTION
E28 – TIMEOUT ERROR IN THE TELEGRAM RECEPTION
E29 – INACTIVE FIELDBUS COMMUNICATION OR PROFIBUS MASTER IN STOP FAULT
E30 – FIELDBUS BOARD IS INACTIVE
E31 – KEYPAD CONNECTION FAULT
E32 OR A32 – MOTOR OVERTEMPERATURE
E33 OR A33 – MOTOR OVERTEMPERATURE CH1
E34 OR A34 – MOTOR OVERTEMPERATURE CH2
E35 OR A35 – MOTOR OVERTEMPERATURE CH3
E36 OR A36 – MOTOR OVERTEMPERATURE CH4
E37 OR A37 – MOTOR OVERTEMPERATURE CH5
E39 – WITHOUT PT106 OPTIONAL BOARD
E41 – SELF-DIAGNOSIS FAULT
E43 OR A43 – CH1 MOTOR TEMPERATURE BROKEN CABLE
E44 OR A44 – CH2 MOTOR TEMPERATURE BROKEN CABLE
E45 OR A45 – CH3 MOTOR TEMPERATURE BROKEN CABLE
E46 OR A46 – CH4 MOTOR TEMPERATURE BROKEN CABLE
E47 OR A47 – CH5 MOTOR TEMPERATURE BROKEN CABLE
E48 OR A48 – CH1 MOTOR TEMPERATURE SHORT CIRCUIT
E49 OR A49 – CH2 MOTOR TEMPERATURE SHORT CIRCUIT
E50 OR A50 – CH3 MOTOR TEMPERATURE SHORT CIRCUIT
E51 OR A51 – CH4 MOTOR TEMPERATURE SHORT CIRCUIT
E52 OR A52 – CH5 MOTOR TEMPERATURE SHORT CIRCUIT
E57 – FAILURE IN SCR R-U
E58 – FAILURE IN SCR S-V
E59 – FAILURE IN SCR T-W
E62 – START LIMITING TIME
E65 OR A65 – UNDERCURRENT
E66 OR A66 – OVERCURRENT
E67 – INVERTED PHASE SEQUENCE
E70 – UNDERVOLTAGE AT THE ELECTRONICS
E71 – BY-PASS CONTACT IS OPEN
E72 – OVERCURRENT BEFORE BY-PASS CONTACT
E74 – CURRENT IMBALANCE
E75 – FREQUENCY OF SUPPLY LINE OUT OF PERMITTED RANGE
E76 – UNDERCURRENT BEFORE BY-PASS
E77 – BY-PASS CONTACT IS CLOSED OR SCRS IN SHORT-CIRCUIT
E78 OR A78 – UNDERTORQUE
E79 OR A79 – OVERTORQUE
E80 OR A80 – UNDERPOWER
E81 OR A81 – OVERPOWER
E85 – WITHOUT SOFTPLC